REACH testing verifies that products, components, and materials comply with EU Regulation (EC) No 1907/2006, covering Substances of Very High Concern (SVHC) screening and the restricted substances listed in Annex XVII. This technical guide explains the scope of REACH testing items, applicable sample types, analytical methods, and regulatory limits to support manufacturers, importers, and exporters. Testing performed by accredited third-party laboratories provides the documented evidence required for EU market access and supply chain communication.
REACH testing verifies that products, components, and materials comply with EU Regulation (EC) No 1907/2006, covering Substances of Very High Concern (SVHC) screening and the restricted substances listed in Annex XVII. This technical guide explains the scope of REACH testing items, applicable sample types, analytical methods, and regulatory limits to support manufacturers, importers, and exporters. Testing performed by accredited third-party laboratories provides the documented evidence required for EU market access and supply chain communication.
Technical Overview
REACH (Registration, Evaluation, Authorisation and Restriction of Chemicals) is the European Union regulation (EC) No 1907/2006, in force since 1 June 2007 and administered by the European Chemicals Agency (ECHA). It applies to chemical substances on their own, in mixtures, and in articles, making it one of the broadest chemical compliance frameworks in the world.
For manufacturers and importers of articles, compliance testing generally focuses on three elements:
- The SVHC Candidate List, which currently contains more than 240 substances and is updated by ECHA approximately twice a year.
- Annex XIV, the Authorisation List, which requires explicit authorisation for specified uses of listed substances.
- Annex XVII, which imposes concentration limits and use restrictions on substances such as cadmium, nickel, azo colorants, chromium(VI), PAHs, and phthalates.
Any article containing an SVHC above 0.1% by weight (w/w) triggers information duties under Article 33, and if the total quantity exceeds one tonne per year per producer or importer, notification duties under Article 7(2). Chemical analysis at accredited third-party laboratories is the practical means of demonstrating that these thresholds are not exceeded and of protecting against customs holds and market surveillance actions.
Testing Samples
Textiles and Apparel
Fabrics, yarns, prints, coatings, buttons, zippers, and labels are tested for azo colorants, formaldehyde, nonylphenol ethoxylates (NPEO), phthalates in plastisol prints, PFAS in water-repellent finishes, and SVHC screening of accessory components.
Leather Goods and Footwear
Leather, synthetic leather, adhesives, and outsoles are analyzed for chromium(VI) formed during tanning, azo dyes, formaldehyde, PAHs in extender oils, organotin compounds, and chlorinated paraffins.
Plastics, Rubber, and Polymeric Materials
Pellets, moldings, films, cables, and elastomers are screened for phthalate plasticizers, short-chain chlorinated paraffins (SCCP), bisphenol A, siloxanes (D4, D5, D6), brominated flame retardants, and PAHs in rubber goods.
Electrical and Electronic Products
Housings, insulation, solder, batteries, and printed circuit boards are commonly tested under REACH in combination with RoHS programs, focusing on phthalates in wires and enclosures, halogenated flame retardants, and SVHC in metallurgical and polymer parts.
Toys and Childcare Articles
Toys are subject to stricter limits, including reduced PAH thresholds, phthalate restrictions, formamide in foams, and SVHC screening of all mouthable and skin-contact components.
Metals, Coatings, and Surface Treatments
Metals and treated surfaces are tested for nickel release from skin-contact parts, cadmium in coatings and plastic colorants, lead in paints, and chromium(VI) in chromate conversion coatings and anti-corrosion primers.
Chemicals, Mixtures, and Packaging
Raw substances, formulations, inks, adhesives, and packaging materials undergo impurity screening, substance identity confirmation, and safety data sheet support to satisfy registration and downstream user obligations.
Testing Items
SVHC Candidate List Screening
SVHC screening packages range from high-frequency substance lists (approximately 60 to 80 analytes) to full-list scans of more than 240 compounds. Common SVHC groups include:
- Phthalates and related plasticizers, including DEHP, DBP, BBP, DIBP, and DCHP.
- Heavy metals and their compounds, including lead, cadmium, cobalt, and arsenic species.
- Polycyclic aromatic hydrocarbons (PAHs) and their derivatives.
- Bisphenol A and related endocrine-disrupting compounds.
- Per- and polyfluoroalkyl substances (PFAS), including PFOA, PFNA, PFHxS, and HFPO-DA.
- Short-chain and medium-chain chlorinated paraffins (SCCP and MCCP).
- Organotin compounds such as TBT, DBT, TOT, and DOT.
- Formaldehyde, siloxanes D4/D5/D6, aniline, and methoxyethanol derivatives.
Annex XVII Restricted Substances
Representative restrictions and limit values applied during testing include:
- Cadmium: 0.01% (100 mg/kg) in plastics and surface coatings (Entry 23).
- Nickel release: 0.5 µg/cm² per week for articles in prolonged skin contact (Entry 27).
- Organotin compounds: 0.1% limits for DBT and DOT in specified materials and articles (Entry 20).
- Pentachlorophenol: 5 mg/kg maximum in treated articles (Entry 22).
- Azo colorants: 30 mg/kg per listed carcinogenic amine (Entry 43).
- SCCP: 0.15% in articles and 1% in substances and mixtures (Entry 46).
- Chromium(VI): 3 mg/kg in leather articles and leather components (Entry 47).
- PAHs: 1 mg/kg per substance in rubber or plastic components of consumer articles, reduced to 0.5 mg/kg for toys and childcare articles (Entry 50).
- Phthalates DEHP, DBP, BBP, and DIBP: 0.1% individually and in sum in plasticized materials (Entries 51 and 52).
- Lead: 0.05% in accessible parts of consumer articles that may be mouthed or handled (Entry 63).
- Nonylphenol ethoxylates: 0.01% in textile articles (Entry 46a).
- Formaldehyde: emission value of 0.062 mg/m³ for furniture and wood-based articles (Entry 72).
Testing Methods
Samples are first reduced to homogeneous materials by cutting, milling, or cryogenic grinding, followed by solvent extraction (ultrasonic, Soxhlet, or microwave-assisted) for organic analytes or acid digestion for elemental analysis. Instrumental techniques are selected according to analyte class:
- GC-MS and GC-MS/MS: phthalates, PAHs, SCCP, azo amines after reductive cleavage, and organotins after derivatization.
- HPLC and LC-MS/MS: formaldehyde, bisphenol A, PFAS, and thermally labile SVHC compounds.
- ICP-OES and ICP-MS: total lead, cadmium, nickel, arsenic, cobalt, and other elements after acid digestion.
- UV-Vis spectrophotometry: hexavalent chromium quantification in leather digests.
- X-ray fluorescence (XRF): rapid non-destructive screening of elements prior to confirmatory wet-chemistry analysis.
Recognized reference methods include EN 14362-1 and EN 14362-3 for azo colorants, ISO 17075-1 and ISO 17075-2 for chromium(VI) in leather, EN ISO 14184-1 for formaldehyde in textiles, EN 1811 with EN 12472 for nickel release from coated items, the IEC 62321 series for elements and phthalates in electrotechnical products, and EN 71-3 as a complementary migration method for toys.
Applications
REACH test reports are used across the product lifecycle and supply chain for the following purposes:
- Demonstrating conformity for EU market access and responding to customs or market surveillance authority inquiries.
- Fulfilling contractual compliance requirements imposed by brand owners, retailers, and importers.
- Generating Article 33 SVHC information and supporting Article 7(2) notification decisions.
- Guiding material selection, substitution of restricted substances, and eco-design programs during product development.
- Documenting chemical management performance for ESG reporting, green public procurement, and corporate sustainability audits.
- Combining with RoHS, POPs Regulation, and toy safety testing to build a consolidated chemical compliance dossier.
FAQ
Is REACH testing legally mandatory?
The regulation itself imposes obligations on manufacturers and importers rather than mandating laboratory testing. In practice, accredited third-party laboratory reports are the standard evidence used to demonstrate compliance, and most EU buyers require them as a condition of purchase.
How often is the SVHC Candidate List updated, and do reports expire?
ECHA updates the list approximately twice per year. Reports are generally considered valid for the list version current at the time of testing; re-testing is recommended after each significant list update or whenever materials, formulations, or suppliers change.
What does the 0.1% w/w SVHC threshold mean?
The threshold applies to each article as defined in the regulation, and for complex products, each independently identifiable component is typically assessed as an article. Concentrations above 0.1% trigger supplier information obligations and potentially ECHA notification duties.
How is REACH different from RoHS?
REACH covers virtually all articles placed on the EU market and focuses on SVHC communication plus broad restriction limits, while RoHS restricts ten specific substances in electrical and electronic equipment. Many electronic products require both test programs, and they are frequently executed together on shared samples.
How many SVHC items should be tested?
The scope depends on buyer specifications, risk assessment, and material type. Cost-effective screening usually targets the high-frequency SVHCs relevant to the product category, while full-list scans of 240 or more substances provide maximum assurance for high-risk or high-volume exports.
What sample quantities and lead times are typical?
Approximately 10 to 20 grams of each homogeneous material are needed for focused testing, with larger quantities required for full-list SVHC scans. Standard turnaround is typically 5 to 7 working days, with expedited 3-day service available from many accredited laboratories.
Why Choose ZKGX?
- State-of-the-art analytical equipment
- Highly qualified scientific team
- Fast turnaround time
- Competitive pricing